Patent No. 10-1315827 (Elevator main power power saving device)
Standby power saving device
Standby Power Reduction Elevator
What is a standby power reduction device?
It is a device that reduces the economic loss by preventing unnecessary power loss by converting the elevator to standby power mode during the operation standby time waiting for a passenger’s call and cutting off continuous power supply to control devices and inverters.
Elevator waiting time is 3 times the actual operating time
Units\Items | number of Operating | Driving distance | Operating time | Driving distance/ 1 Run |
Operating time/ 1 Run |
Per hour Number of driving(18:00 |
peak hours | |
---|---|---|---|---|---|---|---|---|
19th floor | 1 month | 24,241 | 520,000 | 8.811 | 21.3(m) | 21.6(sec) | 1,843 times | 17:00~20:00 |
1Day | 814 | 16,744 | 284 | 59 times | ||||
23rd floor | 1month | 26,055 | 711,000 | 11.479 | 27.3(m) | 27.3(sec) | 1,964 times | 17:00~19:00 |
1Day | 840 | 22,935 | 369 | 63 times |
Elevator operation characteristics (19th, 23rd, 33pyeong (only 25pyeong), step type)
The number of times of elevator operation by time period (19th floor, tiered)
[A Study on Elevator Load Characteristics (June, 1996) Korea National Housing Corporation Housing Research Institute]
The number of times of elevator operation by time (23rd floor, cascading)
[A Study on Elevator Load Characteristics (June, 1996) Korea National Housing Corporation Housing Research Institute]
Standby power saving effect (test result)
Test time | power consumption(Wh) | Reduction | Note | ||
---|---|---|---|---|---|
Normal standby | Application of standby power reduction device | Amount of electricity(Wh) | Ratio | ||
6 hours | 1,792.50 | 396.0 | 1,396.5 | 78% | |
1 hours | 299.1 | 68.5 | 230.6 | 77% |